Seed Germinator (Double Chamber) – Dual-Zone Digital Germination Cabinet
Double-chamber germinator with two independently controlled zones – run two crops or two temperature regimes at once. Doubles throughput for busy seed labs and university departments.
₨550,000.00
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Payment Methods:
Description
The Seed Germinator (Double Chamber) is a dual-zone climate cabinet that gives the lab two independently controlled germination chambers in one footprint. Each chamber has its own digital temperature controller, humidity reservoir, and lighting timer, so the lab can run two different crops, two temperature regimes, or a testing batch alongside a research trial simultaneously.
For Pakistani seed certification laboratories, high-volume private seed companies, and university departments, chamber time is the bottleneck: with hundreds of lots arriving at sowing season, a single chamber forces a queue. Two independent chambers let the lab process wheat and maize germination tests side by side, or run an official 25 C wheat test in one zone while a breeding trial needs 30/20 C alternating conditions in the other. That flexibility is exactly what accreditation assessors and university research supervisors look for.
Key benefits include fully independent dual-zone control, the same precision temperature (+/- 1 C) and 90-95% RH humidity as single-chamber models, energy savings versus running two separate units, individual plexiglass inner doors so checking one chamber never disturbs the other, and double capacity in roughly the same floor space.
Typically supplied with the double cabinet, 4+4 adjustable stainless-steel shelves or trays, two water reservoirs, power cable, and operation manual. Germination papers and dishes ordered separately.
Ideal for provincial seed testing laboratories, seed certification departments with high sample volumes, agricultural universities with teaching plus research loads, large seed companies with in-house QC labs, and research institutes running parallel germination studies.
Key Features
- Two fully independent chambers with separate digital controllers
- Run two crops or two temperature regimes simultaneously
- Temperature range typically 5 to 50/60 C per chamber, +/- 1 C accuracy
- Humidity 90-95% RH in each chamber from separate water reservoirs
- Independent day/night lighting timers per chamber
- Forced-air circulation in each zone for uniform conditions
- Separate plexiglass inner doors – inspecting one chamber does not disturb the other
- Double the throughput in a single floor footprint
Specifications
| Chamber type | Double chamber, independently controlled |
|---|---|
| Chamber volume | 250 – 500 L total (125 – 250 L per chamber typical) |
| Controllers | Two independent dual-display microprocessor PID controllers |
| Cooling | Hermetically sealed compressor(s) |
| Humidity range | 90 to 95% RH per chamber |
| Inner material | SS-304 stainless steel |
| Lighting | Interior fluorescent/tube lighting with 0-24 hr timer per chamber |
| Outer material | MS sheet, powder coated |
| Power consumption | ~1.2 – 2.5 kW |
| Power supply | AC 220-230V, 50Hz |
| Shelves | 4 + 4 adjustable stainless-steel shelves |
| Temperature range | 5 to 50 C per chamber (some models to 60 C), accuracy +/- 1 C |
How to Use
- Position the cabinet on a level floor with rear ventilation clearance and fill both water reservoirs.
- Connect to 220V power; set temperatures and light timers independently for each chamber.
- Allow 30-60 minutes for both chambers to stabilize; verify displays.
- Load samples into each chamber per its protocol; close both inner plexiglass doors.
- Monitor water levels in both reservoirs during long runs and top up with distilled water.
- Log conditions per chamber so dual runs stay traceable for certificates.
- After tests, record germination counts and return unused chambers to idle.
- Safety/maintenance: disinfect both chambers monthly, keep both door gaskets clean, never overload one zone to the point of blocking air circulation, and calibrate controllers annually.